Flue draught must be within parameters 12 ± 2 Pa.
The chimney must be at least 0,5 meters above the roof ridge (see
Figure 2
). The minimum distance between the two connections on the
same chimney must be 60 cm (
Figure 6d
).
Chimney diameter is chosen according to information provided by the
chimney manufacturer – e.g., for flue draught of 12 Pa, the diameter is
usually 130 mm.
The chimney must be smooth on the inside, well insulated and well
fastened. All cleaning hatches must be well fastened. All gaskets must be
regularly inspected and replaced when necessary.
4.3.
CONNECTING TO CHIMNEY
When connecting the cooker to the chimney it is necessary to adhere to
local, national and European regulations (norms) – DIN 4705.
It is necessary to ensure that the connection between the cooker and
the chimney is executed tightly and impermeably. Smoke outlet pipe
must have a suitable incline (minimum 3°) in cases where the cooker is
removed from the chimney opening.
Smoke outlet pipe must not penetrate into the chimney clear
opening (
Figure 6c
).
It is not allowed to reduce the prescribed pipe diameters!
Differences between the proper and improper connection of the cooker
to the chimney are displayed in the following figure.