Make sure that the outdoor air inlet is protected against blockage by
means of a protective grating.
For the supply air duct to the combustion air connecting piece it is best
to use a non-combustible, flexible aluminium hose. Max. length 4 m with
3 bends.
The supply air duct must be insulated to avoid condensation and must
be protected against wind!
According to the regulations for chimney sweeping and inspection
ventilation systems must be checked for blockages once a year by the
local qualified chimney sweep. To facilitate this, appropriate inspection
doors should be provided. Please consult your local qualified chimney
sweep regarding this matter.
4.5.
OVEN THERMOMETER
Thermometer (18) indicates the oven temperature; this value is
informative. If the oven temperature exceed 300
C, the oven must be
partly opened to prevent damage to the thermometer, oven door hinge
and oven door.
The warranty will be void in case the damage to the parts listed before
occurred from excessive oven temperature.
4.6.
INSTALLATION TESTING
Prior to initial firing it is necessary to check if the smoke uptake pipe is
properly fastened.