SENKO cookers SG –
Instruction manual
15
4.
INSTALLATION
Once you have removed packaging from the cooker, it is necessary to
make a detailed inspection in order to determine any potential damages
that might have occurred during transport. Nay detected damages must
instantly be reported to the manufacturer.
In places of any connection points on the cooker (chimney, air inlet),
inspection hatches must be installed for system maintenance and
servicing purposes.
4.1.
POSITIONING
A spirit level must be used to place the cooker in a horizontal
position with no incline. It is necessary to ensure the minimum distance of
the cooker from any flammable objects; such as wood, chipboard, cork
and similar. If the materials are easily combustible such as PVC,
polyurethane and similar, the necessary safety distances need to be
doubled.
The minimum distance from any flammable surfaces above is 1000 mm
and in front of the cooker is 800 mm, and 200 mm in all other directions.
When mounting the cooker on the floor made from easily combustible
material (wooden floors), the cooker must be mounted on an insulating
non-combustible surface.
A 200 mm
from the rear wall
B 200 mm
from the side wall
C 800 mm
from the front side
D 500 mm
floor protection
E
300 mm
(measured from the
maximum angle of firebox door
opening)
F Floor protection
G Radiation area
SENKO
cooker