Combustion air supply via pipe line through a basement room
The combustion air is preheated with this connection option, which is
favorable to a clean combustion. The routing in the basement room is easy
to make.
B)
Combustion air supply via a basement room
The combustion air is preheated. The basement room must be excluded
from the home ventilation system and be open to the outside. High levels
of dust and moisture should be avoided.
C)
Combustion air supply from above
An air supply from above may only be performed with tested chimney
systems. A chimney calculation is mandatory here!
D)
Combustion air supply directly from outdoor
With an air supply directly through the outside wall, the combustion air
is only slightly preheated, which is unfavorable to a clean combustion.
There is also the danger of condensation
!
NOTE: This version of the air supply is not recommended!
Please be aware!
A prerequisite for the connection of cooker used in combination with
domestic ventilation systems is that the approval of the local qualified
chimney sweep is obtained!
It is not permitted to install cut-off devices in the supply air duct
(dampers, sliders, etc.). To prevent air from permanently flowing
through the appliance when it is not in use, close the dampers in the
appliance.