SENKO cookers SG –
Instruction manual
39
10.
TECHNICAL DATA
SENKO cooker
SG-50
SG-60
SG-75
SG-90
Nominal heat output, kW
6
7,5
Room, kW
6
7,5
Width, mm
500
600
750
900
Depth, mm
650
Height, mm
850-920
Weight, kg
149
158
135
170
Firebox opening (W×H), mm
285×120 380×120
165×230
Firebox (W × D), mm
330×170 400×170
205×425
Firebox volume, dm
3
12,9
15,6
27,4
Fuel consumption, kg/h
1,7
2,2
2
Cooking plate (W × D), mm
390×440 458×440 667×492 817×492
Cooking plate area, m
2
0,172
0,202
0,328
0,401
Oven (width), mm
260
360
330
400
Oven (height), mm
200
260
270
230
Oven (depth), mm
440
Ash pan, L
2,1
2,5
Primary air connection, mm
80
Flue gases exhaust, mm
120
Flue gas temperature, °C
230
255
260
235
Required flue draught, Pa
12
CO in flue gases at 13% O
2
,%
0,13
0,21
0,16
Flue gas mass flow rate, g/s
8,3
9,4
10,6
Efficiency, %
75
72
Regulation
Primary air
manual
Secondary air
automatic
manual
Produced in accordance with
EN norm
EN 12815
Energy efficiency class
A
-
technical specification apply to wood logs and wooden briquettes used as fuel
-
technical specifications are indicative and may vary as such. The manufacturer
withholds the right to change any technical specification to further improve the
products