SENKO cookers SG –
Instruction manual
28
Figure 13
5.4.2.
OPTIMUM USE VALUES
Primary air volume and chimney flue draught must be adjusted to levels
that prevent oven temperature from exceeding 300°C.
Maximum quantity of fuel that can be accommodated in the firebox:
2-3 kg (wood); 1,5-2 kg (briquettes).
Adding fuel in regular intervals, in quantities of 0,5 to 1 kg, is
recommended.
When using the oven for baking, it is recommended (to maintain
constant temperature in the oven) to add 0,5 kg of fuel in regular intervals.
It is also recommended to rotate the tray from 180
halfway through the
baking process to ensure uniform baking!
Cooker optimum values may be achieved only if the cooker nominal
power was chosen in accordance with the rules of profession and object
energetic efficiency.
5.4.3.
ADDING FUEL
Apart from use of appropriate fuel and satisfactory chimney flue
draught, the manner in which the cooker is fuelled also influences the
glass cleanness.
We recommend only one layer in each fuel refill and, if possible, the
use of logs of length up to 2/3 of the firebox length. There should be a
minimum distance of 1-2 cm between the logs.