manualshive.com logo in svg
background image

V-ZUG Ltd

Operating instructions
E-Nr GK11TGA
E-Nr GK51TPGA

GK11TG, GK51TPG

Содержание GK11TGA

Страница 1: ...V ZUG Ltd Operating instructions E Nr GK11TGA E Nr GK51TPGA GK11TG GK51TPG ...

Страница 2: ...re regulator supplied with the appliance must be installed in line with the gas pipe N G only For pressure testing in excess of 3 5 kPa 1 2 psig the appliance and its individual shutoff valve must be disconnected from the gas supply piping system Important When using a very large pot leave a gap of at least 50 mm 2 to avoid damaging any parts in bench top wood plastic or other non heat resistant m...

Страница 3: ... NOT THE MANUFACTURER SHALL HELD LIABLE Installation Statutory requirements This installation must conform with the following Manufacturer s Installation instructions Local Gas Fitting Regulations Municipal Building Codes Refer to AS NZS 5601 1 for Gas Installations S A A Wiring Code Local Electrical Regulations Any other statutory regulations Preparing to install Refer to AS NZS 5601 1 for piping...

Страница 4: ... If the base of the hotplate can be touched a protecting shield must be fitted The shield must be at least 10 mm from the lowest part of the hotplate and must be capable of withstanding the appliance temperatures Minimum thickness of benchtop is 30 mm If an oven is positioned below the cooktop the barrier does not need to be fitted but a space of 35 mm must be maintained between the underside of t...

Страница 5: ...tion to the main gas line The hotplate can be connected with rigid pipe as specified in AS NZS 5601 1 Flexible Hose If installing with a hose assembly install with a hose assembly that complies with AS NZS 1869 AGA Approved 10 mm ID class Bor D no more than 1 2 m long and in accordance with AS NZS 5601 1 Ensure that the hose does not contact the hot surfaces of the hotplate oven dishwasher or any ...

Страница 6: ...housings Use the disassembly lever 483196 available from our Service Centre To release the front clips apply the lever in the area shown in figures below according to the cooktop model Never use the lever on glass edges which have no trim or frame To release the rear clips carefully raise the entire glass panel and frame Changing the outer flame nozzle 1 Loosen the clamp screw to release the bushi...

Страница 7: ...mall flame position Screw the adjustment screw anti clockwise to estabilish a minimum stable flame position The flame should remain alight and not burn back to the injector when the valve is turned quickcly from Full On to the Minimum flame position and back a few times To adjust the minimum flame position for Propane gas the screw must be fully tightened down clockwise 4 Refit the control knobs I...

Страница 8: ... after 15 seconds the flame does not ignite switch off the burner and open a nearby window or door Wait at least one minute before trying to switch the burner back on Safety system Depending on the model your hob may have a safety system thermocouple that prevents the flow of gas if the burners accidentally switch off To ensure that this device is active 1 Switch on the burner as usual 2 Without r...

Страница 9: ...the flame has yellow patches this is not a fault of any kind Cooking recommendation Cooking pans Suitable pans The chart below gives the correct pan usage for each burner Precautions for use The following advice is intended to help you save energy and prevent pan damage Inner and outer flame on full power Outer flame on low power inner flame on full power Inner flame on full power Inner flame on l...

Страница 10: ...rom cleaning fruits and vegetables will scratch the glass surface Melted sugar or foods which contain a lot of sugar which may have spilt should be cleaned off the hotplate immediately using the glass scraper Service Sometimes certain faults detected can be easily resolved Before calling the Technical Assistance Service bear in mind the following advice Do not cook without using a lid and make sur...

Страница 11: ...r Check that the coupling is sound Possible gas leak Shut off the gas supply ventilate the premises and immediately notify an authorised installation techni cian to check and certify the installation Do not use the appliance until ensuring that there is no gas leak in the installation or appliance itself The burner immediately switches off after releasing the control knob The control knob was not ...

Страница 12: ... V ZUG Ltd CH 6301 Zug 2012 V ZUG Ltd Industriestrasse 66 CH 6301 Zug vzug vzug ch www vzug com J302 360 0 9000899997 Cod 9000899997 A ...

Отзывы: