3-48
(2) MEDIA ADV
VALUE
Adjust the media advance value. Enter a media
advance value based on the media advance
correction pattern print result.
# M E D I A A D V V A L U E
# X X X X X X > 0 9 9 . 8 1 %
XXXXXX: Media name
<Parameter (numeric input)>
97.00 to 106.00%
Media advance correction value setting range
(3) BACK ADJUST PRINT
When making the media back adjustment (when
PH CLEANING [DURING PRINT] is selected), print
the media back correction pattern. Select the
parameters to meet the respective print mode.
# B A C K A D J P R I N T
> N O R M A L
<Parameter (choice input)>
NORMAL1
Selected when adjusting in the NORMAL1 or DENSITY2 print mode.
QUALITY
Selected when adjusting in the QUALITY or DENSITY2 print mode.
DRAFT1
Selected when adjusting in the DRAFT1 print mode.
FINE DRAFT
Selected when adjusting in the FINE DRAFT print mode.
NORMAL2
Selected when adjusting in the NORMAL2 print mode.
(4) BACK ADJUST
VAL
Set the back adjust value of the media. Enter
a media back value based on the media back
correction pattern print result.
# B A C K A D J V A L
# X X X X X X > + 0 0 0 0 P
XXXXXX: Media name
<Parameter (numeric input)>
±2000 pulses (Unit: Approx. 2.5 μm)
Note
The back adjust value of the media is valid when DURING PRINT is set for PH
CLEANING. (