Maintenance
112
12.00 | SWS | Assembly and Operating Manual | en | 389456
Mount new sensor assembly
Ø
Screw hexagon nut (7) onto new sensor (6).
Ø
Screw the new sensor (6) with washer (8) into the sensor
assembly (2) until sensor (6) touches the detection shaft (9).
Ø
Unscrew sensor (6) again by half a turn.
Ø
Look at the sensor assembly from above.
Ø
Check that the detection shaft (9) and sensor (6) do not touch
each other, readjust the distance if necessary.
Ø
Apply screw lock to the thread of the sensor (6).
Ø
Tighten the hexagon nut (7).
✓
Max. tightening torque: 2.3 Nm
Check new sensor assembly
Ø
Connect the sensor cable (5).
Ø
Switch on power supply.
✓
The sensor LED will illuminate.
✓
Sensor signal is ON.
Ø
Connect all compressed air lines.
Ø
Mount the SWK (3) to the adapter plate for sensor assembly (1)
with screws (4).
✓
Observe the wrench size of the hexagon socket wrench and
the max. tightening torque of the mounting screws for each
size, see table "Mounting the SWK to the adapter plate for
sensor assembly",
Wrench sizes and tightening torques
84].
Ø
Lock and unlock the locking piston and check the signals of the
sensors.