Assembly
34
12.00 | SWS | Assembly and Operating Manual | en | 389456
5.2.1 SWS 001
Mounting on robot for SWK 001
Ø
Clean the mounting patterns on the robot (1) and SWK (2).
Ø
Mount optional adapter plate between the robot and SWK.
Ø
Insert the SWK (2) with integrated dowel pins into the bores on
the robot.
Ø
Apply screw lock to screws (3).
Ø
Secure SWK (2) to robot (1) with screws (3).
✓
Observe the tightening torque for the mounting screws.
Item Mounting
SWK 001
3
Mounting screw according to
standard
M3 x 14,
DIN EN ISO 10642
Strength class
8.8
Max. tightening torque [Nm]
0.79
Threadlocker
Loctite ® 222