Maintenance
12.00 | SWS | Assembly and Operating Manual | en | 389456
113
7.8.3 Change sensor ready-to-lock
SWK 076
SWK 110, 160
Change sensor ready-to-lock
Ø
Place the SWA in the storage rack, secure and uncouple it.
Ø
Disassemble the SWK from the robot and safely set the SWK
aside,
Removing the product from the robot arm
Ø
Hold the ferromagnetic object against the sensor surface and
test the presence monitoring LED.
Ø
Switch off the power supply and ensure that there is no residual
energy in the system.
Ø
Remove the compressed air hose.
Ø
Loosen screw (1).
Ø
Remove sensor (2).
Ø
Only for SWK 076:
Guide new sensor cable out from between
mounting kit and SWK.
Ø
Apply screw lock to screw (1).
Ø
Fasten sensor (2) with screw (1) in recess (3).
✓
Max. tightening torque: 0.4 Nm
Ø
Hold the ferromagnetic object against the sensor surface and
test the presence monitoring LED.