Maintenance
110
12.00 | SWS | Assembly and Operating Manual | en | 389456
Mount new sensor assembly
Ø
Screw new sensor (5) into SWK (3) until sensor (5) touches the
detection shaft.
Ø
Turn the sensor (5) half a turn out of its fitting.
Ø
Look at the sensor assembly from above.
Ø
Ensure that the detection shaft (7) and sensors (5) do not touch
each other, readjust the distance if necessary.
Ø
Apply screw lock to screw (6) and fasten sensor (5) with
screw (6).
IMPORTANT! Risk of damage to the sensor! Carefully screw in
screw (6) until screw (6) touches the sensor, then tighten an
additional approx. 1/4 turn.
Check new sensor assembly
Ø
Switch on power supply.
✓
The sensor LED will illuminate.
✓
Sensor signal is ON.
Ø
Mount the SWK (3) to the adapter plate for sensor assembly (1)
with screws (4).
✓
Observe the tightening torque for the mounting screws.
Ø
Connect all compressed air lines.
Ø
Lock and unlock the locking piston and check the signals of the
sensors.