Maintenance Procedures
6
Front u
pp
er
p
anel
Hou
s
in
g
Viru
s
Wa
s
her element
Ta
bs
Outlet filter ca
s
e
Outlet filter
Joint
Tu
b
e
Pre
ss
S
u
pp
ort
b
racket
S
crew
s
Pre
ss
(1)
(2)
2. Maintenance Procedure
1. Replacing the Virus Washer element
The Virus Washer element must be periodically replaced. It is possible for the customer to replace the
element, however a regular maintenance contract is recommended.
The Virus Washer element must be replaced (at charge to the customer) once a year.
Contact the dealer where the system was purchased.
Stop the system and unplug the power cord.
Then disconnect the front upper panel.
Press at the points marked “PUSH” at the top left and right of the front upper panel,
then pull the top of the panel toward you to remove it.
1
Use a Phillips-head screwdriver to remove the
4 screws, then remove the housing (styrofoam).
2
G
Verify that the system is stopped and the power cord has been unplugged.
CAUTION
Remove the outlet filter case.
(1) Press inward and disengage the front tabs.
(2) Pull downward.
3
Remove the support bracket.
Remove the 2 screws.
4
Disconnect the tube from the joint.
Press evenly at the locations indicated by the
arrows to disengage the lock. Then pull out
the tube while continuing to press. If only one
side is pressed, it will not be possible to
disconnect the tube.
5
Remove and replace the element.
Wipe away any dirt or scale that has
accumulated in the electrolysis tray grooves.
6
6
- 3