2
- 9
2
Using this System
6. Troubleshooting
1. Error notification
The CHECK lamp on the display blinks to indicate an error.
For servicing, contact the dealer where the system was purchased.
2. The following conditions are not malfunctions.
Before requesting servicing, check the following. If the problem is still not corrected, contact the dealer
where the system was purchased.
* If no air is emitted when 3 minutes have elapsed after the ON/OFF button was pressed, contact the dealer where
the system was purchased.
Trouble
Cause
Correction
Has the power plug come out of the
socket?
The ADD WATER lamp is ON.
There is no water in the water tank.
The ADD WATER lamp is ON although
there is water in the water tank.
There is an odor in air coming from
the outlet.
Is old water being used?
(Has the DRAIN lamp been ON
for a long period of time?)
Have the filters or electrolyzed
water tray become fouled?
There is a chlorine smell when the
system is first used, or when
operation starts.
This is caused by the generation of
electrolyzed water.
The odor will diminish when the
system has operated for some time.
(approximately one-half day)
If the odor does not diminish, change
the electrolysis condition setting.
A bubbling sound can be heard.
This is the sound of water being
supplied from the water tank.
This is not a malfunction. Continue
to use the system as-is.
A humming sound can be heard.
This is the sound of the fan operating.
The fan will start when approximately
3 minutes have passed.
No air comes out of the outlet.*
No lamps light when the ON/OFF
button is pressed.
Securely insert the power plug all
the way to the base and press the
ON/OFF button.
Add tap water to the water tank, and
press the ON/OFF button again.
Did you press the ON/OFF button
again?
Press the ON/OFF button again.
Perform draining and drying.
Clean the intake filter.
Have 3 minutes passed since the
ON/OFF button was turned ON?
There is the sound of running water.
This is the sound of water draining to
the drainage tank.
Dispose of the water in the drainage
tank.
Do not disassemble or modify.
G
Do not disassemble or modify this system.
Doing so may result in fire, electric shock, or injury.
WARNING
The SAVER lamp is ON.
(The fan speed is reduced.)
Is the room humidity 80% or higher?
When the room humidity falls to 70%
or lower, the original fan speed will
be restored.
07-032 VW-VF10BG_TD 2/15/07 11:24 AM Page 10