Specifications
4
- 2
4
1. Product Specifications
G
Be sure to use normal tap water. Using well water or purified water as-is may cause system failure.
G
In order that this product can remain in good condition and provide many years of reliable service, consumable parts must be
replaced regularly. For details, refer to “Replacing Consumable Parts” in the Instruction Manual that was provided with the system.
G
If the high collection filter is installed, the airflow will be decreased.
*1: Be sure to use normal tap water (drinking water). Depending on the water quality in your area, it may be necessary to
change the system settings. In addition, the tap water in certain areas cannot be used as-is. For details, refer to “Setting the
Electrolysis Condition” and “List of Water Quality Regions” in the Instruction Manual that was provided with the system.
*2: The operating noise was measured in an anechoic chamber. Therefore it is the value at a position 1 m in front of the system
and a height of 1 m. When the unit is actually installed, ambient noise and noise reflection ordinarily result in noise that is
greater than the value indicated here.
*3: Continuous operating time refers to the operating time when the water tank is full (6 L).
Model
n
ame
Vir
us
Wa
s
her
S
y
s
tem (Floor-Mo
un
ted)
Ge
n
eral Model No.
Hei
g
ht
Exter
n
al
dime
ns
io
ns
Operatio
n
Electrical
characteri
s
tic
s
Width
Depth
Net wei
g
ht
Operati
ng
wei
g
ht
Water ta
n
k capacity
Exterior color (M
uns
ell
nu
mber)
Power
s
o
u
rce
Power cord le
ng
th
mm
mm
mm
k
g
k
g
L
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
W
W
A
h
h
dB (A)
dB (A)
m
m
3
/mi
n
m
3
/mi
n
%
VW-VF10BG
790
5
8
0
297
33
3
9 (whe
n
water ta
n
k i
s
f
u
ll)
S
hippi
ng
wei
g
ht
k
g
3
6
S
hippi
ng
vol
u
me
m
3
0.24
Approx. 6
Fro
n
t pa
n
el: NW-K11 (VW white), M
uns
ell val
u
e N
8
.5
S
ide pa
n
el
s
: NW-K12 (VW
g
ray), M
uns
ell val
u
e N4.0
S
i
ng
le-pha
s
e, 220 – 240 V, 50 / 60 Hz
Su
itable floor
s
pace (approximate)
m
2
100
1.7 (parallel pl
ug
with
g
ro
un
di
ng
co
n
tact)
Co
n
trol
s
ectio
n
Di
s
play (LED lamp
s
)
Operati
ng
mode
s
S
ervice temp. ra
ng
e
Water
us
ed
ON/OFF, FAN
S
PEED, LOUVER, FILTER RE
S
ET,
CHILD LOCK, DRAIN/DRY
OPERATION, HUMIDITY
S
AVER, ADD WATER,
DRAIN, FILTER, CHECK, TREATED AIR VOLUME
5 –
3
5°C
Tap water (dri
n
ki
ng
water) *
1
Power co
nsu
mptio
n
C
u
rre
n
t val
u
e
Fa
n
de
vice
Model Q
u
a
n
tity
Rated airflow
Motor o
u
tp
u
t (No. of electrode
s
)
Lo
u
ver
Air directio
n
adj
us
tme
n
t ra
ng
e
Co
n
ti
nu
o
us
operati
ng
time *
3
Su
mmer
Wi
n
ter
S
irocco fa
n
1
60 (
8
electrode
s
)
2-flap lo
u
ver (with
s
wi
ng
f
un
ctio
n
, f
u
lly clo
s
ed whe
n
s
topped)
0° – 2
3
° (with air directio
n
po
s
itio
n
memory)
12 (MEDIUM operati
ng
s
peed, air co
n
ditio
ns
: DB 27°C, RH 47
%
)
10 (MEDIUM operati
ng
s
peed, air co
n
ditio
ns
: DB 20°C, RH
3
0
%
)
HIGH / MEDIUM / LOW
HIGH: 150 / MEDIUM:
8
0 / LOW: 70
HIGH: 10 / MEDIUM: 5 / LOW: 2
HIGH:
8
/ MEDIUM: 5 / LOW: 2
HIGH: 49 / MEDIUM:
3
9 / LOW: 29 *
2
HIGH: 49 / MEDIUM:
3
5 / LOW: 29 *
2
HIGH: 2.10 / MEDIUM: 1.20 / LOW: 0.
88
Protective device
Protective thermo
s
tat, f
us
e
Water level detectio
n
Float
S
W, reed
S
W
S
e
ns
or
s
Room temp.
s
e
ns
or, water temp.
s
e
ns
or, h
u
midity
s
e
ns
or
Air filter
s
Pre-filter (i
n
take
s
ide) + Hi
g
h collectio
n
filter (i
n
take
s
ide)
(collectio
n
efficie
n
cy: 76
%
by wei
g
ht method)
S
cale filter
s
No
n
-wove
n
cloth filter
s
(compo
s
ed of 5 layer
s
)
Vir
us
Wa
s
her eleme
n
t
S
tatio
n
ary type
Operati
ng
n
oi
s
e
Water
su
pply method
Water ta
n
k (capacity approximately 6 L)
Drai
n
a
g
e method
Drai
n
a
g
e ta
n
k (capacity approximately 2 L)
Primary acce
ss
orie
s
Tip-over preve
n
tio
n
chai
n
, I
ns
tr
u
ctio
n
Ma
nu
al, I
ns
tallatio
n
I
ns
tr
u
ctio
ns
,
mea
su
ri
ng
s
poo
n
Other acce
ss
orie
s
(optio
ns
)
Hi
g
h collectio
n
fi
n
e-particle filter
Model No.
AFT-HVW10B
Collectio
n
efficie
n
cy
Eq
u
ivale
n
t to 65
%
by colorimetric method
(eq
u
ivale
n
t to 9
3%
by wei
g
ht method)
Rated airflow
Operati
ng
n
oi
s
e
07-032 VW-VF10BG_TD 2/15/07 11:24 AM Page 3