SY265C LC/SY265C LR Excavator OMM
3-20
Operation and Maintenance Manual — 0420
SANY
In case of an emergency, raise the red cover (2) and move
the emergency stop toggle switch (3) backward to shut
down the engine and turn off power to the engine control
module (ECM).
Battery Disconnect Switch
The machine is equipped with a battery disconnect switch
(1). When the switch is moved to the OFF position,
electrical power is disconnected from all machine systems.
Turn the power off when securing the machine for the day,
or as needed for maintenance tasks.
To disconnect the battery power from the machine:
1. Move the key switch to OFF and wait 2 minutes for the
ECM to complete its shutdown.
2. Open the left rear access door. See “Opening the Left
3. Turn the battery disconnect switch to the OFF position.
4. Close the left rear access door.
NOTICE!
• Never turn the battery disconnect switch to OFF while the engine is running.
• After machine shutdown, wait at least 2 minutes for the engine control module (ECM) to
complete its shutdown before turning the battery disconnect switch to OFF.
Failure to follow this notice could damage the machine or cause it to operate improperly.
2
3
Fig. 3-30
0005257
Fig. 3-31
0005348
1