4. Remove the breather cover fasteners (2).
5. Remove the crankcase breather cover (3).
6. Remove the breather (4) and tray (5).
7. Inspect the breather cover and tray for damage.
Replace as necessary.
8. Check for internal obstructions or sludge buildup.
9. Clean the breather cover with hot, soapy water and a
soft brush.
10. Rinse the cover with clean water and dry with
compressed air.
NOTE:
Do not use soapy water to clean or rinse the
breather base (6).
11. Clean the breather base with a damp rag to prevent
water from entering the crankcase.
CAUTION!
•
Do not allow compressed air to come into
contact with skin.
•
Always wear goggles, gloves, and other
personal protective equipment (PPE).
Failure to follow these precautions could result
in injury.
0000247
Fig. 5-23
5
4
3
2
0000248
Fig. 5-24