12. Remove fasteners (5) and the hydraulic return filter
cover (6).
13. Remove the spring (7) and withdraw the return filter
(9).
14. Check the bottom of the return filter housing and
remove any debris.
15. Insert a new return filter in the return filter housing.
16. Replace the O-ring (8).
17. Position the spring (9) on top of the return filter (7).
18. Install the hydraulic return filter cover and tighten the
fasteners.
19. Remove the hydraulic suction strainer cover that was
previously removed and placed over the suction
strainer opening.
Fig. 5-100
0004166
5
6
Fig. 5-101
7
0004161
9
8