Collect Oil Samples
1. Obtain an oil analysis sample kit from a SANY dealer.
2. Operate the machine until the lubricant in the compartment being tested is up to normal operating temperature.
3. Prepare the machine for service. See “Maintenance Safety” on page 2-8.
4. Obtain and send the oil sample for testing in accordance with the instructions included with the sample kit.
Follow the instructions included with the sample kit to send the sample for testing.
Collect an Engine Oil Sample
1. Prepare the machine for service. See “Maintenance
2. Start the engine and operate the machine until all
systems reach normal operating temperature.
3. Shut down the engine.
4. Open the engine compartment door. See “Engine
Compartment Door” on page 4-11.
5. Clean the area around the engine oil dipstick (1).
6. Remove the dipstick.
7. Insert the oil sample tube into the dipstick tube.
8. Collect a sample of engine oil.
9. Remove the oil sample tube.
10. Install the dipstick.
11. Follow the instructions included with the sample kit to send the sample for testing.
NOTICE!
It is critical that all material used to collect the sample is absolutely clean. Failure to follow
this notice can damage equipment and contaminate the sample.