69 / 80
Fault
Remedy
Possible cause
The pull-out
shower head is
leaking or faulty.
Leaks, limescale deposits,
material fatigue.
To continue using the appliance, you can
deactivate the use of the pull-out shower
head in the software (see page 54, figure
15).
For repairs, notify the authorised Customer
Service.
Corrosion in the
cooking cham
ber
Poor water quality
Filter the water. Follow the installation in
structions.
Incorrect cleaner/cleaning
Follow the cleaning instructions.
Limescale, grease, starch and
protein residues not properly
removed.
Clean the cooking chamber thoroughly. En
sure that every last particle of residue is
removed from the surface of the cooking
chamber. Corrosion can form under these
residues.
Iron present in the water sup
ply.
Remove all on-site water supply pipes
made from iron/stainless steel.
Fault display:
Nos. 2003, 2004
Communication fault in the
control system.
Switch off the appliance for 1 minute.
If the fault occurs again, contact the autho
rised Customer Service.
Fault display:
No. 3001
Protective/safety mechanism
in appliance is not respon
ding.
Open the cooking chamber door, allow the
appliance to cool.
Turn the appliance off and on.
If the fault occurs again, contact the autho
rised Customer Service.
The appliance was moved at
temperatures below zero.
Frozen products were stored
in the cooking chamber.
The safety temperature limiter
has tripped because the app
liance has cooled to below
−5
°
C.
Set up the appliance in a warm dry room.
Open the cooking chamber door.
When the safety temperature limiter has
warmed up to above +5
°
C, the safety tem
perature limiter will automatically switch
back on.
Fault display:
Nos. 3003, 3004
Temperature sensor in the
cooking chamber is not re
sponding or has short-circui
ted.
Turn the appliance off and on.
If the fault occurs again, contact the autho
rised Customer Service.
Fault display:
No. 3005
Cooking chamber too hot
Switch off the appliance. Open the cooking
chamber door and allow the cooking cham
ber to cool.
If the fault occurs again, contact the autho
rised Customer Service.
Fault display:
Nos. 3006, 5001
Electric compartment too hot.
The appliance is being heated
by heat sources near to the
appliance.
Allow the appliance to cool. Follow the se
tup instructions.
If the fault occurs again, contact the autho
rised Customer Service.
Содержание VitalityEVO-Easy
Страница 79: ...79 80 ...