2. OPERATION
– 58 –
– 59 –
2.14 During the Storage Period
WARNING
If necessary to operate the machine in indoor storage space, ensure good
ventilation keeping windows and doors open to prevent gas poisoning.
• During storage, operate the machine at least once a month to prevent the oil films on the
lubricated parts from deteriorating and to charge the batteries.
• To prevent the brake linings from sticking to the brake drum, disengage the brake once a
month. Exercise care not to allow the machine to move unexpectedly.
2.15 When the Battery has Discharged
WARNING
• To check and handle the batteries, keep the
engine stopped with the starter switch in the
OFF position.
• The batteries give off explosive gases. Do not
smoke close to the batteries. Keep flames and
sparks away from the batteries.
• The electrolyte is very corrosive and will harm
your clothing or skin. If the electrolyte has
come into contact with your clothing or skin,
flush with sufficient amount of water. In case
the electrolyte has gotten into your eyes, flush
with water and get medical help.
• To disconnect the battery cables, start with the
negative terminal (earth). When connecting,
start with the positive terminal. Do not allow
a metallic item to bridge between the positive
terminal and machine body. This can generate
sparks, causing an explosion.
• Loose battery terminals can cause sparks. An
explosion will result. When connecting the
terminals, make certain that they are tight.
CAUTION
The power-supply voltage of this machine is 24V.
2. OPERATION
– 58 –
When the temperature decreases, the battery capacity will lower, possibly freezing the
electrolyte.
The battery should be maintained in a good state at all times, with care taken to keep it warm
in preparation for use the next morning.
Hydrometer atop the battery permits confirmation of the condition of the battery.
Green .................. Satisfactory
Black .................... Charging is necessary
Semitransparent .. Replacement is necessary
Please refer to “3 PERIODICAL MAINTENANCE” Battery (P.74) for inspection and
maintenance of battery.
2.12 When the Cold Season is Over
When winter is over and the warm season has come, proceed as follows:
• Change oil and fuel with those for use in warm season referring to “Rating” on page 92.
2.13 For a Long Storage Period
For leaving the machine unused for longer than one month, proceed as follows:
1) Store the machine in a closed area after cleaning.
2) Conduct oiling, greasing and changing of oil.
3) Grease lubricate the exposed portion of hydraulic cylinder piston rods.
4) Cover the battery after disconnecting the negative cable or take off the battery from the
machine and store in a safe place.
5) If the temperature is expected to go down below 0°C, add antifreeze to the coolant.
6) With F-N-R lever placed at neutral position
Ⓝ
and vibrator switch at "
" position, have the
parking brake engaged.
7) Chock the machine.
8) Remove the starter key.