Connecting power
5-4
Chapter 5: Connecting power
98-136280-B
The length is multiplied by 0.5 above because there are two conductors in the
cable.
If the TT-6080A Power Supply is used, use R
source
= 0 mOhm.
Examples for using the TT-6080A Power Supply:
AWG11
max
=0.5 x (60 mOhm-0)/4.8 mOhm/m = 6.2 m
AWG10
max
=0.5 x (60 mOhm-0)/3.8 mOhm/m = 7.9 m
5.3
Connecting power
To connect the power cable to the ACU
1. Connect the positive and negative input terminals to the ship's DC supply according
to the recommendations in the previous sections.
2. Connect the power plug to DC Input.
For information on pin-out, see
Maximum
length
0 5
Rmax Rsource
–
Rwire
=
Figure 5-2: Connecting power to DC Input
+ —