INTEGRA-X User Manual
WEB GUI
SAF Tehnika JSC
73
5)
Remote IP address
– shows the IP address of the remote (far-end) Integra-X. By default, the
remote IP address is being retrieved automatically and therefore the “Auto” checkbox is
selected. In modify mode you can unselect the “Auto” option and enter the remote IP
address manually. Remote IP address manual setting is used only to establish IP connection
from Local device to Remote device, but will not modify the real IP address on Remote
device.
6)
By pressing
„Execute configuration”,
changes made to the corresponding section apply only
to the local side Integra-X.
CLI commands
See Chapter 4: COMMAND LINE INTERFACE
system ip addr [<IP>]
Use to show/set the IP address of management CPU.
system ip gw [{<IP>|clear}]
Use to show/manage the IP address of the gateway.
system ip mask [<mask>]
Use to show/set subnet mask.
system ip mac
Use to show the MAC address of management CPU.
system ip cfg {<ip address>
<mask> | <ip address> <mask>
<gateway> | <ip address/CIDR>
| <ip address/CIDR>
<gateway>}
Use to set IP address and subnet or optionally IP
address, subnet mask and gateway simultaneously.
system remoteip show
Use to show the remote IP address.
system remoteip auto
Use to set automatic retrieving of the remote IP address.
system remoteip set <IP>
Use to define remote IP address (deactivates automatic
retrieving of remote IP address).
system diag ping <IP_address>
Use to ping an IP address.