INTEGRA-X User Manual
WEB GUI
SAF Tehnika JSC
29
Rollback procedure is triggered only when management connectivity of the devices has
been lost due to the applied configuration changes. For this reason,
„Rollback on”
option
should be selected only when radio link between Local and Remote site has been already
established and synchronized. Rollback will not work in case Remote side of the link has
not been reachable before configuration change took affect and selection of this option
will even display pop-up internal error message in Integra-X WEB GUI.
If you do not save the configuration after modification, it will be lost after the FODU
restart. Indication on unsaved configuration will be shown in always visible
MODIFY/SAVE/LOGOUT section on right top part of the WEB GUI page with red
circle on SAVE button and white number indicating amount of unsaved
configuration changes on the device:
Single polarization mode
For single polarization operation choose Channel A for Vertical or Channel B for Horizontal
polarization, see
on page
Single polarization mode main window status
Figure 3-12 Single polarization Main status page
Local and Remote sides of the link are represented. In the single Channel (polarization) mode,
only two columns will be shown – Local for Channel A or B and Remote for Channel A or B. For
configuring XPIC mode, see
on page
1)
License remaining time
– time left until the capacity of the system will be limited to the
minimum (2Mbps). If the time limitation is not active, “Unlimited” will be shown. Refer to
the Chapter
for further details.
2)
Mode
– system working mode, choose Channel A for the Vertical polarization, Channel B
for the Horizontal polarization. For XPIC configuration see
on page
3)
Tx capacity
– maximum available Tx capacity according to the configured modulation
scheme, bandwidth, and system operational mode.
4)
Rx capacity
- maximum link available Rx capacity with configured maximal modulation
schema, current bandwidth, and system configuration.
5)
Radio side
– “Low” or “High” side, depends on working frequencies of the link, not
modifiable.
6)
Tx mute
– Tx mute status, configurable in
page. Allows turning transmitter
power off. It may be effective when diagnosing interference existence – when transmitter