2-wire DC power port
It is possible to power up Integra-X using screw type terminal block, pluggable, 2 pins, centerline
5.08mm/0.2 inch port. See
Figure 7-2 DC power port
This port can be used together with PoE as a redundant power solution (existing 48V source or
SAF power supply) or as the only power source for Integra-X FODU. Please see “
on page
below for maximum power cable length based on AWG wire size or cross-
section area and Integra-X FODU power consumption when power source is 48V.
Table 7-3
AWG
Cross-section
area, mm
2
Lmax@85W, 48V,
20°C (68°F)
Lmax@95W,
48V, 20°C (68°F)
Lmax@100W,
48V, 20°C (68°F)
26
17m/ 55ft
15m/ 49ft
14m/ 47ft
24
27m/ 87ft
24m/ 78ft
23m/ 74ft
0.25
33m/ 109ft
30m/ 98ft
28m/ 93ft
22
42m/ 138ft
38m/ 124ft
36m/ 118ft
20
0.5
67m/ 218ft
60m/ 195ft
57m/ 185ft
0.75
100m/ 327ft
89m/ 293ft
85m/ 278ft
18
107m/ 350ft
95m/ 313ft
91m/ 298ft
1
130m/ 426ft
116m/ 381ft
110m/ 362ft
16
170m/ 557ft
152m/ 498ft
144m/ 473ft
1.5
194m/ 638ft
174m/ 570ft
165m/ 542ft
14
270m/ 885ft
241m/ 792ft
229m/ 752ft