INTEGRA-X User Manual
WEB GUI
SAF Tehnika JSC
31
Single polarization mode main window modify
Figure 3-13 Single polarization modify page
1)
System working mode
– choose Chanel A for the Vertical polarization and Channel B
for the Horizontal polarization. For XPIC mode configuration see page
2)
Tx power
- the available range depends on the radio model and selected modem
profile. The actual range will be indicated in the brackets.
3)
Tx frequency
- The available frequency range is indicated in the brackets. TX frequency
range indicates the range of central frequencies for the configured channel bandwidth.
4)
Bandwidth profile
-
Allows choosing between available channel bandwidth options,
single mode options have SNGL suffix.
5)
Modem profile
- Allows choosing between available channel modem profile options
along with the selection of fixed modulation type or maximum modulation for ACM
6)
State
-
Allows enabling/disabling each of three available LAN ports.
7)
Execute
- By pressing
„Execute configuration”,
changes made to the corresponding
section apply only to the local side Integra-X. If
„Rollback on”
is selected, the
configuration will be reverted in case erroneous configuration changes are applied.
Execute for both
-
applies changes made to the corresponding section both for local
and remote side Integra-X FODUs. If
„Rollback on”
is selected, the configuration will be
reverted in case erroneous configuration changes are applied.
Rollback triggers when configuration changes applied interrupted management
connectivity. For this reason, rollback will not work if the remote side of the link was not
reachable before configuration change took place.