alarm will be generated; when the servo motor may have unsafe operation, a servo alarm will
also be generated. There are several situations in which a servo alarm may occur:
The servo drive has generated an alarm. Please power on the servo drive again.
When the servo motor speed exceeds the maximum speed, a servo alarm will be
generated. Please increase the maximum speed or reduce the running speed.
When the servo motor acceleration exceeds a certain value, a servo alarm will be
generated. Please check if the servo driver encoder wiring is correct and check if the
encoder polarity setting is correct.
The alarm signal voltage logic of servo driver is incorrect. When the servo driver alarms,
the output must be high voltage. If it is low voltage, please switch the voltage to high by
relay or other ways.
The wiring is wrong, please check the connection.
Poor grounding, resulting in large system interference, resulting in false triggering of the
alarm, please ensure that the machine is well grounded.
7.1.12
Machine protection
After the machine protection function is enabled in the manufacturer parameters, and the
mainboard detects that the machine protection input (general input port I8) is in high voltage or
floating, the main board will generate an alarm for machine protection. If it is in processing, the
machining will be suspended. . If you need to continue processing, please eliminate the alarm
fault first, then continue processing, otherwise you will not be able to continue processing.
7.1.13
Following alarm
During cutting, when the Z axis triggers an alarm (such as a collision alarm, etc.), the Z axis
will automatically protect the lifting automatically, and the panel will show the following alarm, and
the main board will suspend processing.
7.1.14
Machine alarm
After the laser function is enabled in the manufacturer parameters, and the main board
detects that the laser alarm input is high voltage or floating, the main board will generate an
alarm. If it is in processing, the processing will be suspended. If you need to continue
processing, please eliminate the alarm fault first, and then continue processing, otherwise
you will not be able to continue processing. There are several possible situations in which a
laser alarm can occur:
The laser machine has generated an alarm. Please re-power on the laser.