RDC6563F Standalone Fiber Cutting Control System User Manual V2.0
105
SHENZHEN RUIDA TECHNOLOGY CO., LTD
Trigger upper and lower limit
switches during [capacitor
calibration]
In
[capacitor
calibration],
manually move the cutting
head off the limit switch
。
The motor does not actually
rotate and causes a timeout
to exit.
First ensure that the motor
can move normally
The height following
is significantly
different from the
actual height
No capacitor calibration for a
long time
Re-capacitor calibration
No
recalibration
of
the
capacitor after replacing the
capacitor sensor and other
accessories
Re-capacitor calibration
Part of the laser is scattered
onto the capacitive sensor,
causing
the
nozzle
temperature to rising.
Please check if the lens is
clean and the laser is not
biased.
Blowing causes a large
change in the detected
capacitance value
Please check if the gas is dry
and pure
When following,
there is a serious
jitter
Poor contact of the amplifier
shell (or metal plate) with the
machine
Ensure that the amplifier
shell (or metal plate) is in
good
contact
with
the
machine
Filter coefficient setting is too
large
Reduce the filter coefficient
No capacitor calibration or
calibration results are not
good
Re-capacitor calibration
Plate shake caused cutting
shake when blowing
Appropriate increase of jitter
filtering time
Servo drive rigidity setting is
too large
Reduce servo stiffness
Large machine interference
Connect the height adjuster
PGND to the machine shell
while connecting the shell to
the earth