![RuiDa RDC6563F Скачать руководство пользователя страница 55](http://html1.mh-extra.com/html/ruida/rdc6563f/rdc6563f_user-manual_1499548055.webp)
RDC6563F Standalone Fiber Cutting Control System User Manual V2.0
54
SHENZHEN RUIDA TECHNOLOGY CO., LTD
triggered, no protection will be generated.
Servo alarm
enable
If the servo alarm is enabled, protection will be generated
when the servo drive alarms; if the servo alarm is
disabled, no protection will be generated when the servo
drive alarms.
Collision
capacitance
It is used to set the capacitance value of the nozzle when
it touches the plate. This parameter must be set correctly,
otherwise, it may happen that the plate is touched
repeatedly or the collision alarm is mistakenly triggered
when the film is calibrated. When setting this parameter,
manually move the z-axis to move the nozzle to the
height that just touches the metal plate, and the
capacitance value displayed on the plate is the value of
the colliding plate capacitance.
LASER
MACHINE
Laser enable
Laser type can choose fiber laser, glass tube and RF
tube, please according to the actual situation of the
machine enable laser.
Pre-enable
For non-fiber lasers, the pre-ignition mode can be used.
Predicted
frequency
When it is a radio frequency laser and a pre-ignition
pulse is required, the characteristics of the pre-ignition
pulse can be configured by the pre-ignition frequency
and the pre-ignition pulse width.
Predicted pulse
width
When it is a radio frequency laser and a pre-ignition
pulse is required, the characteristics of the pre-ignition
pulse can be configured by the pre-ignition frequency
and the pre-ignition pulse width.
Maximum power
The system limits the maximum power that the laser can
output.
Minimum power
The system limits the minimum power that the laser can
output.
Laser frequency
Laser PWM output signal frequency.
Laser ON signal
valid
Set the laser ON signal logic level
Laser alarm
enable
When the laser alarm is enabled, when the laser
generates an alarm, the motherboard will generate
protection, otherwise it will not be protected.
Enable
parameter
Machine
protection enable
When the signal is externally input, it can be connected
to external devices such as water tanks and sliding