4.1 Follow-up system function
4.1.1 Servo calibration
The purpose of servo calibration is to eliminate the zero drift of the servo motor. Due to the
servo calibration, the motor will move back and forth in a small amount. Therefore, it is necessary
to jog to the middle of the stroke to prevent the stroke range from being exceeded or the limit
switch being touched. If the alarm, such as limit, collision alarm, servo alarm, etc., is triggered
during servo calibration, the servo calibration processes will stop.
。
Enter the servo calibration interface by [Function] → [Servo Calibration] on the panel, and
then press [Enter], the interface as following:
When confirm that it is correctly, press the [Enter] key to perform servo calibration. If you
cancel the calibration during the calibration process, press the [Exit] key.
After the calibration is completed, press the [Enter] key to save the calibration result.
4.1.2 Capacitor calibration
Capacitor calibration is the process of automatic calibration of the servo system. If the
temperature and humidity of the external environment are changed for a long time, it is