Fuji A5 series servo drive wiring instructions
Fuji A5 series servo drive parameter setting instructions
Parameter Type
Settings
Description
PA-101
01
Set to speed mode
PA-108
2500
The encoder pulse number
is 10000
PA-115
17
Rigid rating
PA-303
02
—
PA-331
6.0
Speed gain is set to
500r/min/V
2.11 Limit switch interface
The limit switches supports both normally open and normally closed. The limit switch can
use mechanical contact switch, photoelectric switch, and proximity switch and support 5V or 24V
output voltage.
The two typical connections for photoelectric switches are shown below: