9 | Menu | 9.4 | Input/Output Routing: The Global Routing Settings
EN-122
SurroundMonitor 11900 Series
•
Standard Settings Digital
(Does NOT apply for Peakmeter – Channel Group 3 in
Surround modes and 2 Channel Stereo mode)
This combo box applies to the parameters grouped direct-
ly below it.
After selecting
digital
or
aRd
, these combo boxes are
automatically set to values corresponding to the
digital
or
aRd
standards. After editing any of these combo boxes
manually (except the
PH integration time
combo box
and the
Operation indicator area
combo box), the text
„Non Standard“ is displayed in the
Standard Settings
digital
combo box. Reselecting
digital
or
aRd
automati-
cally resets all parameters grouped below to the standard
values of these presets.
NOTE -
The
Standards Settings digital
combo
box and the related parameters are only available after a
digital signal source has been selected in the
Metering
Routing
section of the
Key 1
to
Key 7
menu pages.
NOTE -
Depending on the selected standard, so-
me of the parameters might not be available.
•
Scale
(Does NOT apply for Peakmeter – Channel Group 3 in
Surround modes and 2 Channel Stereo mode)
The following scales are available in this combo box:
•
Dig60dB
(–60 dBFS to 0 dBFS,
Standard Settings
digital
: selection:
digital
)
•
Dig20dB
(–20 dBFS to 0 dBFS)
•
Dig+18 dB... 0 dB
(0 dBFS = +18 dB)
•
Dig+18 dB... 0... –18 dB
(0 dBFS = +18 dB)
•
Dig+20 dB... 0... –40 dB
(0 dBFS = +20 dB)
•
ARD +9 dB... –60 dB
(0 dBFS = +9 dB,
Standard
Settings digital
: selection
aRd
)
•
<q> DIN 5 dB
(quasi-DIN scale,
–9 dBFS = 0 dB)
•
<q> DIN 10 dB
(quasi-DIN scale,
–9 dBFS = 0 dB)
•
<q> ARD +9 dB... –60 dB
(quasi-DIN scale,
0 dBFS = +9 dB)
•
<q> Zoom +/– 10 dB
(quasi-DIN scale,
–9 dBFS = 0 dB)
•
<q> Zoom +/– 1 dB
(quasi-DIN scale,
–9 dBFS = 0 dB)
•
<q> Nordic
(quasi-Nordic scale,
–9 dBFS = +6 dB)
•
<q> British IIa
(quasi-British scale,
–9 dBFS = “6”)
•
<q> British IIb
(quasi-British scale,
–9 dBFS = +8 dB)
•
Integration time
(Does NOT apply for Peakmeter – Channel Group 3)
This combo box selects the integration time of the level
display:
•
10 ms (Standard Settings Digital: Selection ARD)
•
20 ms
•
1 ms
•
0.1 ms
•
Sample (Standard Settings Digital: Selection Digital)
•
PH Integration Time
(Does NOT apply for Peakmeter – Channel Group 3 in
Surround modes and 2 Channel Stereo mode)
This combo box sets the integration time for the peak hold
display:
•
Integration Time: Uses the same integration time
as for the level display (Standard
Settings Digital).
•
Sample:
Uses a sample-precise integration
time that is independent of the
level display.
•
DC-Filter
(Does NOT apply for Peakmeter – Channel Group 3 in
Surround modes and 2 Channel Stereo mode)
This combo box sets the DC filter. It can be switched
off
or set to
5 Hz
(Standard Settings Digital),
10 Hz
or
20 Hz
.
•
Headroom
(Does NOT apply for Peakmeter – Channel Group 3 in
Surround modes and 2 Channel Stereo mode)
This list box sets the beginning of the headroom in the
range between –20 dBFS and –5 dBFS. The digital stan-
dard setting (Standard Settings Digital) is
–9 dBFS
.
NOTE -
The headroom of the
ARD+9 dB..–60
dB
scale is fixed to
–9 dBFS
.
•
Operation indicator area
(Does NOT apply for Peakmeter – Channel Group 3 in
Surround modes and 2 Channel Stereo mode)
This list box defines the threshold for the operating area in-
dicator. Values between –20 dB and 0 dB are available. The
digital standard setting (Standard Settings Digital) is 0 dB.
Содержание SurroundMonitor 11900 Series
Страница 1: ...SurroundMonitor 11900 Manual ...
Страница 2: ...SurroundMonitor 11900 ...
Страница 3: ...DE SurroundMonitor 11900 Serie Bedienungsanleitung ...
Страница 8: ...Sicherheitshinweise DE 6 SurroundMonitor 11900 Serie ...
Страница 12: ...Inhaltsverzeichnis DE 10 SurroundMonitor 11900 Serie ...
Страница 42: ...7 Steuerung 7 4 Extern über die GP IO Schnittstelle steuern DE 40 SurroundControl 31900 31960 Serie ...
Страница 94: ...8 Instrumente Anzeigearten 8 15 Das BLITS Instrument DE 92 SurroundMonitor 11900 Serie ...
Страница 156: ...9 Menü 9 12 Key Settings Menü Key Settings DE 154 SurroundMonitor 11900 Serie ...
Страница 191: ...EN SurroundMonitor 11900 Series Operating Manual ...
Страница 196: ...Safety Instructions Attention EN 6 SurroundMonitor 11900 Series ...
Страница 200: ...Content EN 10 SurroundMonitor 11900 Series ...
Страница 280: ...8 Instruments Display Modes 8 15 The BLITS Instrument EN 90 SurroundMonitor 11900 Series ...
Страница 342: ...9 Menu 9 12 Key Settings The Key Settings Menu EN 152 SurroundMonitor 11900 Series ...