7 | Control | 7.4 | External control via GP IO connector
EN-38
SurroundMonitor 11900 Series
5. After wiring all determined connections, connect the
counter plug to the
GP IO
connector of the SurroundMo-
nitor unit.
6. Connect the unit to power supply and power it on.
7. Press the
Menu
button. The menu system is initialized.
8. Use the
<
or
>
button to select the
GPIO Configurati-
on
menu tab. The
Global GPIO Settings
menu page is
displayed.
9. Use
Ù
or
Ú
button to set the focus to the
Function
com-
bo boxes of the
Outputs
you have to change. Confirm
with
red Sel
(SELECT) key.
10. Use
Ù
or
Ú
button to set the focus on the function option
you need (
Key Preset
or
alarm
). Enter the selection by
pressing the
red Sel
(SELECT) key.
11. Repeat steps 7 and 8 for the other output functions you
have to change.
12. Use
Ù
or
Ú
buttons/keys to select the
Output Signal Ti-
ming
combo boxes and the
Output Logic
combo boxes.
Confirm by pressing the
red Sel
(SELECT) key. Proceed
as described in steps 7 to 9.
13. If you have assigned the alarm function to outputs, use
<
or
>
key to select the Alarm Configuration menu tab. The
Global Alarm Setting menu page is displayed.
14. Use
Ù
or
Ú
buttons/keys to set the focus to the on
checkbox of the
alarm general Settings
frame. Enter
the selection by pressing the
red Sel
(SELECT) key.
15. Use
Ù
or
Ú
buttons/keys and the
red Sel
(SELECT) key
to select other options you need to change.
16. In the
Alarm-Event Type Selection
section, only the
Out-
put
combo boxes which have been assigned with the alarm
function (as described before, steps 7 to 8) are available.
17. Use
Ù
or
Ú
key to set the focus to one of the combo
boxes. Confirm by pressing the
red Sel
(SELECT) key.
18. Use
Ù
or
Ú
key to select the option you need. Confirm by
pressing the
red Sel
(SELECT) key.
19. Use
<
or
>
key to select the
instrument Settings
menu
tab. The
instrument Settings
menu page is displayed.
20. Use
Ù
or
Ú
key to set the focus to the
edit selected
preset
button. Confirm by pressing the
red Sel
(SELECT)
key.
21. Use
<
or
>
key to select the
Local Input/Output
Routing and instrument Settings
menu tab. The
local
Routing Settings
menu page is displayed.
22. Use
Ù
or
Ú
key to set the focus to the
Input Routing
button. Confirm by pressing the
red Sel
(SELECT) key.
23. On the
Key 1
to
Key 7
menu pages, use the
Ù
or
Ú
button to select one or more of the check boxes labelled
GPIO 1 to 8
depending on your definition of the output
switching state for this key. The check boxes of the out-
puts set to the alarm functions are greyed and cannot be
selected.
24. Click the
Save & Exit
button or press the corresponding
key to store the changes and leave the menu. The
Save
Preset
menu page is displayed.
25. Press the
red Sel
(SELECT) key, if you want to select
another User Preset as the displayed one. Use the
Ù
or
Ú
button to set the menu focus to the one you prefer and
press the
red Sel
(SELECT) key.
26. If you want you can change the name of the preset. The
button
change name
opens a keyboard to enter the
name you prefer (6 characters).
27. Click the
Save & Exit
button again to store the changes
and leave the menu. The unit returns to normal operation.
Содержание SurroundMonitor 11900 Series
Страница 1: ...SurroundMonitor 11900 Manual ...
Страница 2: ...SurroundMonitor 11900 ...
Страница 3: ...DE SurroundMonitor 11900 Serie Bedienungsanleitung ...
Страница 8: ...Sicherheitshinweise DE 6 SurroundMonitor 11900 Serie ...
Страница 12: ...Inhaltsverzeichnis DE 10 SurroundMonitor 11900 Serie ...
Страница 42: ...7 Steuerung 7 4 Extern über die GP IO Schnittstelle steuern DE 40 SurroundControl 31900 31960 Serie ...
Страница 94: ...8 Instrumente Anzeigearten 8 15 Das BLITS Instrument DE 92 SurroundMonitor 11900 Serie ...
Страница 156: ...9 Menü 9 12 Key Settings Menü Key Settings DE 154 SurroundMonitor 11900 Serie ...
Страница 191: ...EN SurroundMonitor 11900 Series Operating Manual ...
Страница 196: ...Safety Instructions Attention EN 6 SurroundMonitor 11900 Series ...
Страница 200: ...Content EN 10 SurroundMonitor 11900 Series ...
Страница 280: ...8 Instruments Display Modes 8 15 The BLITS Instrument EN 90 SurroundMonitor 11900 Series ...
Страница 342: ...9 Menu 9 12 Key Settings The Key Settings Menu EN 152 SurroundMonitor 11900 Series ...