M0627-1 version 3.3
17
Check servo power pins
Check that the signal and servo
power pins are clean. For
cleaning and lubrication see
section 3.2.4.
Check that the pins or interface
are not worn-out or damaged. For
replacing the signal or servo
power interface see section 4.3.6.
NOTE!
When interface options,
P1308, P1357, P1355 are used!
Check high voltage pins
Check that the high voltage pins
are clean. For cleaning and
lubrication see section 3.2.4.
Check that the high voltage
interface is not worn-out or
damaged. For replacing the high
voltage interface see section
4.3.6.
NOTE!
When high voltage
interface, P1323, is used!
Check O-rings
Check that O-rings on signal,
power and high voltage modules
are not worn-out or damaged. For
making replacements see section
4.3.7.
NOTE!
When interface options,
P1306, P1312, P1308, P1339,
P1329, P1323, P1357 and P1355
are used!
Clean surface of signal contact
Wipe the contact surface with a
lint free cloth.
NOTE!
When signal interface
options, P1306, P1312, P1339
and P1329, are used!
Check that the signal interface is
not worn-out or damaged. For
replacing the signal interface see
section 4.3.6.
Check cables
Check cables for damages and
squeezing, replace if damaged.
Check tool attachment in general
Check the tool attachment for
damages. For replacement see
section 4.2.
Содержание P1301A