M0627-1 version 3.3
27
4.3.2 Replacement of air sealings on TC60, TC120 and air module, TC-side
Action
Note
1
Remove air sealings
Remove the air sealings with
a screw driver.
NOTE!
There are totally 8 air
sealings on TC60 and TC120
and two air sealings on the
air module.
2
Clean sealing holes
Wipe clean the sealing holes.
Remove all remaining parts
of sealings and glue.
3
Mount new air sealings
Glue the new air sealings in
the sealing grooves. Use a
small amount of Loctite 480
(or similar). Press the sealings
60-120 seconds until the glue
hardens.