30
M0627-1 version 3.3
4.3.5 Replacement of signal, servo power, high voltage interface and air
module, TC-side
Action
Note
1
Power off
Switch the power off and lock
the circuit breaker.
2
Disconnect interface
Remove connector from the
servo power interface.
3
Release interface
Unscrew the four screws and
release the signal interface/air
module.
NOTE!
P1307, P1322, P1356
and P1354 and are mounted
with a special type of shoulder
screw. See spare part list.
4
Mount new interface
Mount a new signal
interface/air module.
.
NOTE!
Tightening torque for
mounting of shoulder screws
are 2 Nm. For standard M4
screws see tightening torques
above.
5
Reconnect interface
Connect the new signal
interface/air module.