Structural surroundings
Min. 25 mm
Max. 8 mm
Avoiding hazardous areas
– The following on-site requirements must be given:
– The distance between the ground and the lower closing edge is less
than 8 mm.
– The distance between the upper edge of the door sash and the room
ceiling is greater than 25 mm.
– There are no obstacles on the ground.
The specifications are dependent on the conducted safety analysis and
the individual assessment of residual risks.
– Should you have any queries or if anything is unclear, please contact your
local Roto specialist dealer.
Lubrication
Purchase all lubrication from your Roto specialist dealer.
As and when required or at least once a year:
Lubricating door latch and locking cam
– Remove any old, excess lubricant using a dry, lint-free cloth.
– Apply one drop of resin-free oil (e.g. Molykote Omnigliss) to moving
parts.
Lubricating door hinge
– Remove any old, excess lubricant using a dry, lint-free cloth.
– Apply a drop of oil to the door hinge (e.g. Molykote Omnigliss).
Care
Specialist company
End-users
Keep the hardware free from deposits and
soiling.
Never use aggressive, acidic cleaning or
scouring agents.
Only use mild, pH-neutral cleaning agents
in diluted form.
Use a soft cloth only for cleaning.
= To be carried out by a specialist company only
–
=
Not
to be carried out by the end-user; the end-user may not carry out installation work!
= To be carried out either by a specialist company or by the end-user
No legal claims can be derived from these recommendations. Application is
to be geared to each specific individual case. The door manufacturer must
ensure that builders and end-users are made aware of the importance of
these maintenance instructions. Roto Frank AG recommends that manufac-
turers enter into maintenance agreements with their end-users.