IMO_294_EN_v0
May 2013
33
4. Programmable output*
The door control is equipped with its own programmable output to which,
e.g. the light in the input area is connected and where it can be configured
such that it is switched on when the door is opened. A small LED lamp can
also be connected, which lights up when authorisation has been issued.
It is also possible to configure the output so that it is only briefly actuated,
in other words it flashes on and off briefly or it is permanently activated.
NOTE!
In the standard wiring the signal for the programmable output is
not routed out of the door.
DIP switch
Description
Feedback signal
Personal setting
0 1 1 0
0 0
0 0 Feedback on current status
–
0 1
General setting:
Continuous signal as long as
authorisation issued
1
1 0 General setting:
Continuous signal if not closed
2
1 1 General setting: Precision setting at bottom
3
0 1
0 0 Feedback on current status
–
0 1 Signal when opening: None
1
1 0 Signal when opening:
Output activated for 0.5 seconds
2
1 1
Signal when opening:
Output activated as long as
actuation issued
3
1 0
0 0 Feedback on current status
–
0 1 Signal when closing: None
1
1 0 Signal when closing:
Output activated for 0.5 seconds
2
1 1
Signal when closing:
Output activated as long as
actuation issued
3
Optional settings
Programmable output