Subject to change.
Roto E-Tec DoorDrive
IMO_294_EN_v0
May 2013
19
Installation
Installation steps
1.
Pull cable type SD with the free end at the top
through the milled recesses in the door sash into the
interior (door panel).
Pull cable type SD in far enough until a protrusion of
approx. 400 mm still projects beyond the upper
milled recess.
2.
Route cable type SD into the glazing rebate up to
the milled recess for the electronic unit. Ensure that
the cable here has sufficiently large bending radii.
Alternatively, the cable can also be routed into the
profile chamber. To do this, the cable must however
have been inserted before the corner connector is
made.
Drill hole
3.
Route the cable type SD through the bore in the
glazing rebate into the profile chamber.
Seal the drill holes to the glazing rebate after routing
the cable with vapour diffusion-proof adhesive tape.