Optional settings
Operating mode, Push to close/Push to open
A service dongle is required for certain individual settings (denoted by * in
the following text), which only the door manufacturer may make. Plug the
service dongle onto the service connector. The correct function is indicated
by the LED on the service dongle lighting up. All the other settings can be
made by the end user.
Illustration of service dongle, the tab acts
as a reverse-polarity protection
Service interface illustration
ON
1
2
3
4
5
6
7
8
Service interface
Roto settings are available in the tables in
bold
. These default values are
replaced during initial operation in step 3.
Individual setting
NOTE!
All settings denoted by * require a service dongle.
1. Operating mode
Setting operating mode on DIP switches 1 – 4 = 0000
DIP switch
Description
Feedback signal
Personal setting
0 0 0 0
0 0 0 0
Normal operation
Basic setting
1 1 1 1 Change to
parameterisation
mode
=
Activate serial
interface
2. Push to close / Push to open
Push to close or Push to open can be set to suit requirements.
In this function several options can be defined for the parameter as sepa-
rate settings can be made for “Push to close / Push to open”.
Push to open means that the door is automatically opened by approx. 10°
following a manual impulse. Push to close is the same except the door
closes here instead of opening.
Setting general functionality / comfort on DIP switches 1– 4 = 0001
DIP switch
Description
Feedback signal
Personal setting
0 0 0 1
0 0
0 0 Feedback on current status
–
0 1 Push to close
OFF
1
1 0
Push to close
ON
2
0 1
0 0 Feedback on current status
–
0 1 Push to open
OFF
1
1 0
Push to open
ON
2
1 0
0 0 Feedback on current status*
–
0 1
1
1 0
2