Manual
Double Sheet Detector R1000 series UDK20
Start-up
B0048991 / Rev. 1.3
94
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
The UP key leads to the following menu item:
Fig. 63: Indicating the nominal thickness for the program
Here the nominal thickness for this program is shown (here: prog. 12).
With the ENTER key and UP/ DOWN keys all programs can be polled / indicated.
The ENTER key will exit the section.
The UP key leads to the following menu item:
Fig. 64: Indicating the factor for the program, investigated on Teach-In
Here the factor (2PW units: both factors) for this program, investigated on Teach-In, is shown
(here: prog. 12).
With the ENTER key and UP/ DOWN keys all programs can be polled / indicated.
The ENTER key will exit the section.
The UP key leads to the following menu item:
Fig. 65: Exiting the factor diagnosis section
The ENTER key will exit the factor diagnostics.
System parameter 13:
Equipment diagnostics (W-diagnosis)
Fig. 66: W-diagnostics
Note
The settings of the current program will be taken over as default settings.
system param. 13
W-diagnostics
system param. 12
P12 EXIT
system param. 12
P12 FKT=1.112
system param. 12
P12 N=2.12mm