Manual
Double Sheet Detector R1000 series UDK20
Start-up
B0048991 / Rev. 1.3
84
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Fig. 33: Selecting the configuration mode
Available configuration modes:
•
Configuration system parameter
•
Configuration program parameter
•
Data backup
System parameters are general adjustments (e.g. language).
Program parameters are application specific adjustments (e.g. input of nominal sheet thickness).
Note
After exiting the configuration mode the password remains active for five
minutes. Thus other configuration adjustments can be made, without re-
entering the password. If no key is pressed (while in the menu level), then
the program changes to the measurement mode
Pos: 56 /Doppelblech/Geräte/UDK20 Bus/7 Inbetriebnahme/Parameter (Programm-) @ 2\mod_1314017995590_501.doc @ 9922 @ 2 @ 1
7.6
Program parameters
The program parameters contain the information required for the various measurement programs.
For accessing the program parameters, select the mode “configuration program parameter“ and
confirm with
ENTER
.
Program parameter 1:
Selecting the measuring program to be configured.
Fig. 34: Selecting the program to be configured
Here the measuring program (1-255) to be configured is selected. All following adjustments apply
to the selected program (here: program no. 1).
Program parameter 2:
Selecting the sensor to be used for measurement.
Fig. 35: Selecting the sensor
Possible choices:
•
2PW-units: 1 / 2 / 1+2
•
with SSB: 1 / 2 / 3 / 4
program par. 1
program no.: 1
program par. 2
sensor: 1
configuration
program param.