Manual
Double Sheet Detector R1000 series UDK20
B0048991 / Rev. 1.3
Start-up
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
93
System parameter 10:
Deactivating / activating the external calibration
Fig. 59: Deactivating / activating the external calibration
Here the external calibration can be deactivated, which is possible via the interface with the signals
“Teach-In 0-sheet“ and “Teach-In 1-sheet“.
System parameter 11:
Setting the output logic (0-sheet, 1-sheet, 2-sheet outputs).
Fig. 60: Setting the output logic
Possible choices:
•
0 V: As shown in the timing diagrams and the wiring diagrams
•
+24 V: The outputs 0-sheet, 1-sheet and 2-sheet are inverted, i.e. the respective signals in
the timing diagrams and wiring diagrams must be seen inverted.
Note
The output “Enable“ is not affected thereby.
System parameter 12:
Equipment diagnostics (Teach-In factors).
Fig. 61: Diagnostics factor
The ENTER key leads to the following menu item:
Fig. 62: Indicating the investigated conductance
Here the conductivity investigated for this program is shown (here: prog. 12)
•
Extra: = slightly magnetical NF material
•
FE = magnetical steel
For NF material the conductivity range is shown.
With the ENTER key and UP/ DOWN keys all programs can be polled / indicated.
The ENTER key will exit the section.
system param. 12
P12 EC:24-32ms/m
system param. 10
ext. adj.: no
system param. 11
output 0-1-2: 0V
system param. 12
diagnost. factor