Manual
Double Sheet Detector R1000 series UDK20
Electrical installation
B0048991 / Rev. 1.3
64
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
5.3
Connecting diagram - examples
5.3.1 Connecting diagram UDK20 with one sensor
1 Cable
Order no.: SCPWS-GG (straight cable socket)
Order no.: SCPWS-GW (90° angle socket)
Superflex (C)Y PURKOMBI 2 x 1,0 mm² + 4 x 2 x 0,25 mm²
1a Cable plug (9 contacts)
Order no.: 2277004
Pin 1
grey
Pin 2
pink
Pin 3
red
Pin 4
black
Pin 5
blue
Pin 6
brown, 1 mm²
Pin 7
brown
Pin 8
white, 1 mm²
Pin 9
green
Enclosure blank (Shield)
1b Cable socket (9 contacts)
Order no.: 2276005 (straight)
2276007 (90° angle)
1
1b
1a
1
1b
Optionale Trennstelle
Pin 1
grey
Pin 2
pink
Pin 3
red
Pin 4
black
Pin 5
blue
Pin 6
brown, 1 mm²
Pin 7
brown
Pin 8
white, 1 mm²
Pin 9
green
Enclosure blank (Shield)
Fig. 23: UDK20 with one PW42AGS sensor