Manual
Double Sheet Detector R1000 series UDK20
B0048991 / Rev. 1.3
Mounting
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
45
Fig. 15: Base plate for sensor holder SHX42
Replacing the gasket
Pull the rubber disc over the lower edge. Pay attention for undamaged sealing lips at the inner and
outer edge as well as for uniform projection of the sealing edge.
The gasket can be bilaterally used.