Manual
Double Sheet Detector R1000 series UDK20
B0048991 / Rev. 1.3
Start-up
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
89
Description of the Teach-In procedure:
Locally at the control unit
With PLC (Bus)
For material
(system parameter 2)
FE
NF / LM
FE
NF / LM
Step 1:
attach sheet and initiate
Teach-In
Measured thickness
will be displayed.
Characteristic curve
will be determined.
Nominal value will be
displayed.
Measured thickness
will automatically
corrected to nominal
value.
Measured thickness
will automatically
corrected to nominal
value.
Correct measured
thickness to nominal
value (e.g. measured
with micrometer
screw).
Correct measured
thickness to nominal
value (e.g. measured
with micrometer
screw).
-
-
Step 2:
Calibration
Max. possible
correction see I.
Correction ± 20% of
nominal value.
Maximal corrected
deviation see II.
Deviation will be
internally corrected.
I.
depending on the set T-limit (system parameter)
a: 66% / 125%:
•
possible upward correction of the displayed thickness:
max. 150 % of the indicated value but not more than 125 % of the set nominal
thickness, but not more than the max. measurable thickness (depending on
sensor; 4mm for PW42AGS)
•
possible downward correction of the displayed thickness:
min. 80% of the indicated value but not less than 66 % of the set nominal thickness
b: 33% / 142%:
•
possible upward correction of the displayed thickness:
max. 300 % of the indicated value but not more than 142 % of the set nominal
thickness, but not more than the max. measurable thickness (depending on
sensor; 4mm for PW42AGS)
•
possible downward correction of the displayed thickness:
min. 70% of the indicated value but not less than 33 % of the set nominal thickness
II.
depending on the set T-limit (system parameter)
a: 66% / 125%:
The ratio of measured to nominal value must be between 66% and 125%
b: 33% / 142%:
The ratio of measured to nominal value must be between 33% and 142%
Attention
For operation with „sequence 1+2“ the values for sensor 1 and 2
may
not deviate from each other for more than ± 20 %.
Pos: 57 /Doppelblech/Geräte/UDK20/7 Inbetriebnahme/Parameter (System-) @ 1\mod_1310624206840_501.doc @ 9544 @ 2 @ 1