Manual
Double Sheet Control System R1000 series L20
with integrated fieldbus interface
Start-up
B0063191 / 1.3
74
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
For changing parameters, the password must be entered.
Fig. 36: Password request
Each blinking digit can be changed with the arrow keys and confirmed with ENTER. After having
entered the correct password, the following menu appears for the selection of sub structure items.
The password is factory set to “0000”.
If the entered password is incorrect then the cursor returns to the first digit of the password and the
input must be repeated. The input of the password can be aborted by pressing the MENU button.
Note
After exiting the configuration mode the password remains active for five
minutes. Thus other configuration adjustments can be made, without re-
entering the password. If no key is pressed for five minutes while in the
menu level, the unit will return to the default state.
Note
A fault is generated if PLC commands are executed while entering the
password or changing parameters.
Selection of sub structure items:
Fig. 37: Selecting the sub structure items
Available sub structure items are:
•
Configuration program parameter
•
Configuration adjustment parameters
•
Configuration system adjust
• Data
backup
•
Firmware update
Program parameters are application specific adjustments (e.g. input of nominal sheet thickness).
Adjustment parameters are parameter, which are only valid for this individual system; they cannot
be transferred to other systems.
System parameters are general adjustments (e.g. language).
password
xxxx
configuration
program parameter