Fault messages, causes and remedies
B0063191 / 1.3
106
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
9.10 Sensors / Sensor cables faults
No. Cause
Remedy
180 Measuring channel 1: Sensor incompatible at connection A
Contact Roland Electronic or replace sensor
181 Measuring channel 1: Sensor incompatible at connection B
182 Measuring channel 2: Sensor incompatible at connection A
183 Measuring channel 2: Sensor incompatible at connection B
184 Measuring channel 3: Sensor incompatible at connection A
185 Measuring channel 3: Sensor incompatible at connection B
186 Measuring channel 1:
Sensor incompatible
187 Measuring channel 2:
188 Measuring channel 3:
190 Measuring channel 1: Sensor not responding at connection A
Check / replace sensor cable; replace sensor
191 Measuring channel 1: Sensor not responding at connection B
192 Measuring channel 2: Sensor not responding at connection A
193 Measuring channel 2: Sensor not responding at connection B
194 Measuring channel 3: Sensor not responding at connection A
195 Measuring channel 3: Sensor not responding at connection A
196 Measuring channel 1:
Sensor not responding
197 Measuring channel 2:
198 Measuring channel 3:
201 Measuring channel 1: Sensor at connection A could not
determine any gap, while the same sensor determined a gap
at connection B
Check if
• Sensor A is contaminated
• Sheet to be measured is out of measuring
window
Further details see system parameter 21
202 Measuring channel 1: Sensor at connection B could not
determine any gap, while the same sensor determined a gap
at connection A
Check if
• Sensor B is contaminated
• Sheet to be measured is out of measuring
window
Further details see system parameter 21
203 Measuring channel 1: The beam alignment is no longer
optimal
Perform system alignment 4 „System
test“/alignment and realign the sensors,
eventually clean the optics
204 Measuring channel 2: Sensor at connection A could not
determine any gap, while the same sensor determined a gap
at connection B
see Nr. 201
205 Measuring channel 2: Sensor at connection B could not
determine any gap, while the same sensor determined a gap
at connection A
see Nr. 202
206 Measuring channel 2: The beam alignment is no longer
optimal
see Nr. 203
207 Measuring channel 3: Sensor at connection A could not
determine any gap, while the same sensor determined a gap
at connection B
see Nr. 201
208 Measuring channel 3: Sensor at connection B could not
determine any gap, while the same sensor determined a gap
at connection A
see Nr. 202
209 Measuring channel 3: The beam alignment is no longer
optimal
see Nr. 203
211 Measuring channel 1:
Communication problems
In case of repeated appearance please contact
Roland Electronic.
212 Measuring channel 2:
213 Measuring channel 3: