![Roland l20 Скачать руководство пользователя страница 55](http://html1.mh-extra.com/html/roland/l20/l20_manual_1479453055.webp)
Manual
Double Sheet Control System R1000 series L20
with integrated fieldbus interface
B0063191 / 1.3
Communication with the PLC
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
55
6.5
External I/O control
The system is normally controlled via the process channel. The exception is the signal
"Measurement start", which, for fast procedures, can also be controlled via the Optocoupler inputs
(IN). A mixed operation is also possible. The control cannot, however, be made simultaneously by
both signal sources.
The “Measurement start“ signals can be initiated via the process channel or the opto couplers. The
“Measurement start“ signals can be initiated via the process channel or the opto couplers.
Simultaneous initiation leads to an error message.
Signal Meaning
Notes
IN0
Measurement start input 1
Optocoupler input 1,
24 V active
IN1
Measurement start input 2
Optocoupler input 2
24 V active
IN2
Measurement start input 3
Optocoupler input 3
24 V active
The “Measurement start“ inputs are linked in different combinations via AND. The following
configuration can be selected in the control unit:
• IN0
•
IN0 and IN1
•
IN0 and IN1 and IN2
In addition the signals “0-, 1-, 2-sheet”, “ENABLE” and “Warning” are available for further
processing via Optocoupler (OUT).
Signal Meaning
Notes
OUT0
Output 0-sheet
1. Optocoupler output
Standard 0 V active (selectable in unit configuration)
OUT1
Output 1-sheet
2. Optocoupler output
Standard 0 V active (selectable in unit configuration)
OUT2
Output 2-sheet
3. Optocoupler output
Standard 0 V active (selectable in unit configuration)
OUT3
Output ENABLE
4. Optocoupler output
Standard 24 V active (not selectable for safety reasons)
OUT4
Warning
5. Optocoupler output
Standard 0 V active (selectable in unit configuration)
Attention
If the external outputs or inputs are used, then the supply voltage for
the outputs / inputs needs to be connected.