Manual
Double Sheet Control System R1000 series L20
with integrated fieldbus interface
B0063191 / 1.3
Communication with the PLC
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
59
6.6
Fieldbus configuration file
The configuration files for the respective fieldbus systems are located on the supplied CD.
6.6.1 GSD file for Profibus-DP
The GSD file contains the specific configuration data of the slave. The data must be known to the
Profibus master.
The manufacturers of the Profibus master supply the tools for the integration of the GSD file into
the Profibus network. Suitable are for example the Siemens step 7 tools. Roland Electronic does
not supply such tools, because they have to be compatible with the interface design of the master.
The GSD file is supplied on a CD or can be downloaded from the Roland homepage.
Note
24 Bytes I/O must be set.
By pressing the key “
▼
” status indicators are shown on the display.
Status Indicators
Nr.
LED
State
Description
LED 1 ---
---
---
LED 2 Fieldbus
Online
Green
Bus online, data exchange possible
Off
Bus not online (or no power)
LED 3 Fieldbus
Offline
Red
Bus offline
Off
Bus not offline (or no power)
LED 4 Fieldbus
Diagnostics
Off
No diagnostics present (or no power)
Red, flashing (1 Hz)
Error in Configuration Data
Red, flashing (2 Hz)
Error in Parameter Data
Red, flashing (4 Hz)
Error in initialization of the PROFIBUS
communication ASIC
Red, flashing (8 Hz)
Watchdog timeout (internal error)